C_LO_FSCLight-only FSC, No Fluxgates operating. Instrument in Config Mode with no Science data transmision to SSMM. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_B_FIBBurst Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_B_FIBFOBBurst Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_B_FIBFOBFSCBurst Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature.JMAG
S_B_FOBBurst Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_G_FIBGradiometer Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_G_FIBFOBGradiometer Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_G_FIBFOBFSCGradiometer Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature.JMAG
S_G_FOBGradiometer Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_L_FIBLow-rate Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_L_FIBFOBLow-rate Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_L_FIBFOBFSCLow-rate Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature.JMAG
S_L_FOBLow-rate Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_LOG_FIBFOBFSCLight-only Gradiometer Mode. FSC Powered but producing no Science data. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_LOG_FIBFSCLight-only Gradiometer Mode. FSC Powered but producing no Science data. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_LOG_FOBFSCLight-only Gradiometer Mode. FSC Powered but producing no Science data. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_LON_FIBFOBFSCLight-only Normal Mode. FSC Powered but producing no Science data. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_LON_FIBFSCLight-only Normal Mode. FSC Powered but producing no Science data. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_LON_FOBFSCLight-only Normal Mode. FSC Powered but producing no Science data. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_N_FIBNormal Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_N_FIBFOBNormal Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_N_FIBFOBFSCNormal Mode The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature.JMAG
S_N_FOBNormal Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_V_FIBValidation Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_V_FIBFOBValidation Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG
S_V_FIBFOBFSCValidation Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature.JMAG
S_V_FOBValidation Mode. The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.JMAG

27 modes