C_LO_FSC | Light-only FSC, No Fluxgates operating. Instrument in Config Mode with no Science data transmision to SSMM.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_B_FIB | Burst Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_B_FIBFOB | Burst Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_B_FIBFOBFSC | Burst Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.
Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature. | JMAG |
S_B_FOB | Burst Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_G_FIB | Gradiometer Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_G_FIBFOB | Gradiometer Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_G_FIBFOBFSC | Gradiometer Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.
Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature. | JMAG |
S_G_FOB | Gradiometer Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_L_FIB | Low-rate Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_L_FIBFOB | Low-rate Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_L_FIBFOBFSC | Low-rate Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.
Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature. | JMAG |
S_L_FOB | Low-rate Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_LOG_FIBFOBFSC | Light-only Gradiometer Mode. FSC Powered but producing no Science data.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_LOG_FIBFSC | Light-only Gradiometer Mode. FSC Powered but producing no Science data.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_LOG_FOBFSC | Light-only Gradiometer Mode. FSC Powered but producing no Science data.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_LON_FIBFOBFSC | Light-only Normal Mode. FSC Powered but producing no Science data.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_LON_FIBFSC | Light-only Normal Mode. FSC Powered but producing no Science data.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_LON_FOBFSC | Light-only Normal Mode. FSC Powered but producing no Science data.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_N_FIB | Normal Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_N_FIBFOB | Normal Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_N_FIBFOBFSC | Normal Mode
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.
Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature. | JMAG |
S_N_FOB | Normal Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_V_FIB | Validation Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_V_FIBFOB | Validation Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |
S_V_FIBFOBFSC | Validation Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter.
Power is 13.3 (+4): The amount of the (+4W) needed is wholly dependent on the vault temperature. When the vault temp is at the minimum allowed then the MAGSCA Peltier needs this additional 4W to get the laser up to temperature. | JMAG |
S_V_FOB | Validation Mode.
The mode naming convention states whether the instrument is in SCIENCE or CONFIG with the first letter, the Macro Mode with the second letter. | JMAG |